Withdrawn IGEM Standards
Why IGEM withdraw Standards
From time to time, IGEM withdraws (makes obsolete) a Standard
without issuing a superseding Standard.
The reasons for such withdrawal may include:
- the Standard is out of date in some respects and the demand for
a replacement is negligible, for example IGE/SR/12 Edition 2
- the Standard is out of date in some respects and, while the
demand for a replacement may be significant, IGEM considered that
other, more up to date , sufficient, standards are available, for
example from BSI, NFPA etc. for example IGE/SR/17
- the Standard has in effect been superseded by other standards
which may be IGEM's or others' such as BSI, for example
IGE/TD/15.
Any IGEM Standard that has been withdrawn is obsolete and IGEM
takes no responsibility if the Standard continues to be applied
beyond its withdrawal date.
Standards that have been withdrawn in the last 3 years (and not
fully superseded by an IGEM Standard) may be available to download
from this website, dependent upon the degree to which the Standard
was considered to be out of date and/or whether other referenced
standards contain all the (more up to date) information from the
withdrawn Standard.
If a withdrawn Standard, or parts of a withdrawn Standard, are not
available to download, then that Standard is either shown to be
inaccurate/outdated to an unacceptable degree, or 3 years has
elapsed since its withdrawal. In both such cases, hard copies can
only be obtained by application to IGEM Technical Services for
which there is a charge for photocopying and postage and electronic
copy is not available.
IGE/ER/1 Edition 2. Communication 1638. Occupational
Hygiene Practice
Withdrawn. Obsolete.
Alternative references: HSE AcoPs and Guidance (www.hse.gov.uk)
IGE/TD/15. Communication 1679. Services and metering
installations for a gas flow not exceeding 6m3h-1 at supply MOP
exceeding 75 mbar but not exceeding 2 bar
Withdrawn. Obsolete.
Alternative references: BS 6400-2 for the meter
installation
IGE/TD/4 for the service (including the emergency control
valve)
Extant Recommendations
IGEM's Gas Measurement Committee has approved the following
relevant text from TD/15 with respect to operation and maintenance
of the meter housing and meter installation. This should be
considered as guidance only and not formal IGEM requirements.
METER HOUSING AND METER INSTALLATION
Routine inspection of the installation should be undertaken at a
period not exceeding 5 years to guard against changes in the
surroundings of the installation due to factors such as building
alterations, extensions or garden landscaping. The following should
be carried out:
-
check the atmosphere around the installation for the presence
of gas. Any leaks should be rectified or reported to the emergency
service provider
-
check that the siting criteria has not been compromised by
building work, landscaping, fitting of electrical apparatus,
etc.
-
check that the meter box has not been damaged such that a
passage of gas would be possible from the installation directly
into the property
-
check that the relief vent pipe is attached securely to the
regulator and that the vent tip is outside the meter box
-
check the installation for water ingress and/or
corrosion
-
check the outlet pressure of the installation.
Records of inspection should be made and retained.
FUNCTIONAL CHECKS ON A METER INSTALLATION
Functional checks should be carried out in accordance with BS
6400-2 at intervals not exceeding 10 years. However, when the
installation comprises a pressure control and safety system
incorporating a relief valve and a meter installation excess flow
valve, the requirement for a periodic functional check on the
operation of these valves should be assessed on the basis of the
operating history of such installations.
Records of functional checks should be made and retained.
MODIFICATIONS
Whenever work, i.e. intrusion into a gasway, is undertaken, tests
as outlined in BS 6400-2 should be carried out.
IGE/SR/12 Edition 2. Communication 1661. Handling of
Methanol
Withdrawn. Obsolete at August 2007.
Download
IGE/SR/12 Edition 2
IGE/GL/3. Communication 1628. Gas supply emergency
procedures
Withdrawn. Obsolete at 2007.
Download
IGE/GL/3